این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 19 آذر 1404
International Journal of Radiation Research
، جلد ۱۵، شماره ۴، صفحات ۳۴۳-۳۵۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Radiobiological and physical effects of patient setup errors during whole breast irradiation
چکیده انگلیسی مقاله
Background: The dose-related effects of patient setup errors on bio-physical indices were evaluated for the conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques (WBI). Materials and Methods: The treatment plans of 10 patients receiving left WBI were retrospectively selected for evaluation. The bio-physical effects of dose variations were evaluated by shifting the isocenters and gantry-angles of the treatment plans. Dose-volume histograms of the planning target volume (PTV), heart, and lungs were generated, and the conformity index (CI), homogeneity index (HI), tumor control probability (TCP), and normal tissue complication probability (NTCP) were determined. Results: The D95 of the PTV for an "isocenter shift plan" with a posterior direction decreased by approximately 15%, and the TCP of the PTV decreased by approximately 50% for the FIF technique and by 40% for the CW; however, the NTCPs of the lungs and heart increased for both techniques. Increasing the gantry-angle decreased the TCPs of the PTV by 24.4% (CW) and by 34% (FIF). The NTCPs of the lungs and heart for the two techniques differed by only 3%. The CIs and HIs for the CW case were higher than the corresponding values obtained for the FIF case. Significant differences were observed between the two techniques (p< 0.01). Conclusion: Our results revealed that the biophysical properties of the FIF case were more sensitive to setup errors than those in the CW case. The radiobiological-based analysis could be detected significant dosimetric errors and provided a practical patient quality assurance method for guiding the bio-physical effects.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
سیدرضا lee | s r lee
department of biomedical engineering, college of medicine, the catholic university of korea, seoul, korea
محمدجواد کیم | m j kim
department of biomedical engineering, college of medicine, the catholic university of korea, seoul, korea
سید حسین سونگ گو | s h park
department of biomedical engineering, college of medicine, the catholic university of korea, seoul, korea
محمدیوسف lee | m y lee
department of biomedical engineering, college of medicine, the catholic university of korea, seoul, korea
تهمینه السادات suh | t s suh
department of biomedical engineering, college of medicine, the catholic university of korea, seoul, korea
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-1-685&slc_lang=en&sid=en
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/42/article-42-568198.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات