این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۶، شماره ۴، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience
چکیده انگلیسی مقاله
Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results of UKR with the new instrumentation in a consecutive serieswith a minimum follow-up of 2 years.Methods: A prospective study of 115 cemented medial Oxford UKRs implanted in 89 patients was done. Postoperativealignment of the tibial and femoral components was analysed. Patient reported outcome measures wererecorded using Oxford Knee Score (OKS) and the American Knee Society Score (KSS). Tegner Activity Scale (TAS)was used to record the activity level.Results: 115 consecutive medial Oxford UKRs were studied. All patients were followed up annually in this prospectiveethically approved study. The mean follow-up was 36 months and the minimum follow-up was 25 months. No patientdied and none were lost to follow-up. At the final follow-up, the average OKS of the cohort was 39.5 (SD: 5.7). 91.2 % ofthe patients had good or excellent OKS with only 3.5 % reporting poor OKS. The overall limb alignment was 4.80 varus(0 – 140 varus). Tibia was recut in 5.2 % of cases. Median bearing size was 3 (range: 3 to 6). There was one case ofbearing dislocation and one case of aseptic tibial loosening.Conclusion: This is the first study to report results of MP instrumentation at a minimum follow-up of 2 years. Our studyindicates that the new instrumentation results in reliable and accurate implantation of femoral and tibial components inmajority of the cases, with a decrease in number of alignment outliers, and also a reduced rate of bearing dislocation.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Sahil Gaba
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| Naman Wahal
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| Deepak Gautam
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| Hemant Pandit
Orthopaedics and Honorary Consultant, Chapel Allerton Hospital, University of Leeds, UK
| Vijay Kumar
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| Rajesh Malhotra
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
نشانی اینترنتی
http://abjs.mums.ac.ir/article_10267.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/328/article-328-689525.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات