این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۲، شماره ۴، صفحات ۲۳۰-۲۳۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Medium-Term Stability of the Photon Beam Energy of An Elekta CompactTM Linear Accelerator Based on Daily Measurements of Beam Quality Factor
چکیده انگلیسی مقاله
Introduction In this study, we aimed to assess the medium-term energy stability of a 6MV Elekta CompactTM linear accelerator. To the best of our knowledge, this is the first published article to evaluate this linear accelerator in terms of energy stability. As well as investigating the stability of the linear accelerator energy over a period of several weeks, the results will be useful for estimation of the required tolerance values for the beam quality factor (BQF) of the PTW QUICKCHECK weblineTM (QCW) daily checking device. Materials and Methods Over a 13 week period of routine clinical service, 52 daily readings of BQF were taken and then analyzed for a 10×10 cm2 field. Results No decreasing or increasing trend in BQF was observed over the study period. The mean BQF value was estimated at 5.4483 with a standard deviation (SD) of 0.0459 (0.8%). The mean value was only 0.1% different from the baseline value. Conclusion The results of this medium-term stability study of the Elekta Compact linear accelerator energy showed that 96.2% of the observed BQF values were within ±1.3% of the baseline value. This can be considered to be within the recommended tolerance for linear accelerator photon beam energy. If an approach of applying ±3 SD is taken, the tolerance level for BQF may be suggested to be set at ±2.5%. However, further research is required to establish a relationship between BQF value and the actual changes in beam energy and penetrative quality.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
محمد امین مصلح شیرازی | mohammad amin mosleh shirazi
physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran 2- ionizing and non-ionizing radiation protection research center, school of paramedical sciences, shiraz university of medical sciences, shiraz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
سعید رحیمی | saeed rahimi
department of medical physics and engineering, school of medicine, shiraz university of medical sciences, shiraz, iran student research committee, shiraz university of medical sciences, shiraz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
ساره کرباسی | sareh karbasi
physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_6835.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Short Communications
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات