این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 29 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۲، شماره ۳، صفحات ۲۰۹-۲۲۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A Novel Spot-Enhancement Anisotropic Diffusion Method for the Improvement of Segmentation in Two-dimensional Gel Electrophoresis Images, Based on the Watershed Transform Algorithm
چکیده انگلیسی مقاله
Introduction Two-dimensional gel electrophoresis (2DGE) is a powerful technique in proteomics for protein separation. In this technique, spot segmentation is an essential stage, which can be challenging due to problems such as overlapping spots, streaks, artifacts and noise. Watershed transform is one of the common methods for image segmentation. Nevertheless, in 2DGE image segmentation, the noise and artifacts of images cause over-segmentation in the watershed algorithm. Materials and Methods In this study, we proposed a novel spot-enhancement anisotropic diffusion (SEAD) method, based on multi-scale second-order derivatives and eigensystemto enhance the spots and remove noise and artifacts. The proposed SEAD algorithm was plugged to a watershed transform in order to improve the performance of watershed segmentation algorithm. Results The performance of the proposed SEAD method was evaluated on synthetic and real 2DGE images. The proposed algorithm was compared with other segmentation methodsin terms of different criteria including efficiency, precision and true positive rate. The performance of the methods were evaluated in the presence of noise and the results were evaluated by t-test. According to the count of detected spots, precision and efficiency of the proposed method were 0.82 and 0.67 respectively. The precision and efficiency values of the comparative methods were as follows: 0.65 and 0.42 for MCW algorithm, 0.40 and 0.37 for BWT method, 0.74 and 0.53 for the method proposed by Kostopoulou and 0.76 and 0.55 for the method proposed by Mylona. Conclusion The comparison of the proposed method with four other conventional methods revealed the superiority and effectiveness of the proposed SEAD method.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
محمد حسین میران بیگی | mohammad hossein miran beygi
faculty of electrical and computer engineering, tarbiat modares university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه تربیت مدرس (Tarbiat modares university)
بهاره آذریان | bahareh azarian
protein-chemistry laboratory, biotechnology research center, pasteur institute of iran, tehran, iran
سازمان اصلی تایید شده
: انستیتو پاستور ایران (Pasteur institute of iran)
علی گویا | ali gooya
faculty of electrical and computer engineering, tarbiat modares university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه تربیت مدرس (Tarbiat modares university)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_6222.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات