Iranian Journal of Medical Physics
، جلد ۱۲، شماره ۲، صفحات ۸۵-۹۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran
چکیده انگلیسی مقاله
Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation dose. Materials and Methods This cross-sectional study was performed on seven stationary X-ray units in sixhospitals of Lorestan province. The measurements were performed, using a factory-calibrated Barracuda dosimeter (model: SE-43137). Results According to the results, the highest output was obtained in A Hospital (M1 device), ranging from 107×10-3 to 147×10-3 mGy/mAs. The evaluation of tube voltage accuracy showed a deviation from the standard value, which ranged between 0.81% (M1 device) and 17.94% (M2 device) at A Hospital. The deviation ranges at other hospitals were as follows: 0.30-27.52% in B Hospital (the highest in this study), 8.11-20.34% in C Hospital, 1.68-2.58% in D Hospital, 0.90-2.42% in E Hospital and 0.10-1.63% in F Hospital. The evaluation of exposure time accuracy showed that E, C, D and A (M2 device) hospitals complied with the requirements (allowing a deviation of ±5%), whereas A (M1 device), F and B hospitals exceeded the permitted limit. Conclusion The results of this study showed that old X-ray equipments with poor or no maintenance are probably the main sources of reducing radiographic image quality and increasing patient radiation dose.
کلیدواژههای انگلیسی مقاله
Quality control, X-ray Output, kVp Accuracy
نویسندگان مقاله
مهرداد غلامی | mehrdad gholami
department of medical physics amp;amp; radiation sciences, school of para medicine sciences, lorestan university of medical sciences, khorram abad, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی لرستان (Lorestan university of medical sciences)
فتانه نعمتی | fataneh nemati
science amp;amp; research branch, islamic azad university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)
وحید کرمی | vahid karami
department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی جندی شاپور اهواز (Ahvaz jundishapur university of medical sciences)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_4770.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات