این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 30 آذر 1404
Iranian Journal of Medical Physics
، جلد ۸، شماره ۳، صفحات ۱۳-۱۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Excess Cancer Risk Assessment from Some Common X-Ray Examinations in Sabzevar County
چکیده انگلیسی مقاله
Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at low doses and include many types of cancer and genetic mutations. So it is very important to assess the risk of exposure in medical examinations. Cancer is one of these hazardous risks caused by low dose ionizing radiation that may occur during life after exposure. According to BEAR 7, low dose radiation is defined as radiation that produces doses near zero up to 100 mSv. Materials and Methods: This work was carried out in eight radiology centers in the Sabzevar county of Iran for 485 patients in eight typical x-ray examinations chosen for the study: chest PA, chest AP, lumbar spine AP, lumbar spine LAT, pelvis AP, abdomen AP, skull AP and Lat. In order to estimate the excess cancer risk, we need to obtain collective effective dose caused by radiation in the study population. Usually effective dose offers precise assessment of radiography examination injuries in adult patients. In this study, we used the PCXMC Monte Carlo based software to obtain effective dose and organ dose. This software calculates organ and effective dose following input of patient and radiographic conditions. Results: Average patient weight and height, entrance surface dose, parameters used for each type of examination, and DAP values were entered. Effective dose, collective effective dose, number of radiographs per year and the excess cancer risk arising from these radiographic examinations were then calculated. Discussion and Conclusion: Excess risk of fatal cancer due to x-ray examinations in the study population was calculated by collective effective dose. This risk in the population is about 0.42 cases suffering fatal cancer per year in this county. If the doses from other diagnostic radiology procedures, in which absorbed dose to patients are considerably higher than conventional radiography, are added to this amount, then the excess risk will be significantly greater than that obtained in this assessment.
کلیدواژههای انگلیسی مقاله
PCXMC Software, Radiography, Risk, Risk Assessment
نویسندگان مقاله
محمد تقی بحرینی طوسی | mohammad taghi bahreyni toossi
prof., medical physics dept., medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)
حسن زرقانی | hassan zarghani
ph.d. student of medical physics, faculty of medicine, mashhad university of medical sciences, mashhad, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_7225.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات