Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
چکیده انگلیسی مقاله
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident angle. Material and Methods: To investigate the spatial resolution and the FOV in VRX CT, we used the numerical parameters of an actual VRX CT scanner. The effects of decreasing the focal spot size and optimizing magnification on the spatial resolution and the FOV of the system were studied theoretically. Results: The focal spot size was found to greatly limit the spatial resolution of the VRX CT at the small incident angles. By decreasing the focal spot size, the spatial resolution was comparatively improved. Optimization of the system magnification without decreasing the focal spot size could greatly increase the spatial resolution of the system. After optimization of magnification, the FOV of the system decreased significantly. Discussion and Conclusion: The spatial resolution of the system after optimizing the magnification increased from 7.5 to more than 35 cycles/mm and also the effect of the focal spot no longer limited the spatial resolution at incident angles smaller than 13˚. The disadvantage of optimization of magnification was a great decrease in the FOV of the system. The optimization of magnification has the reverse effect on the spatial resolution and the FOV of the system so at each incident angle, according to the importance of spatial resolution or FOV, the system magnification can be set to lead to the desirable condition.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
حسین عربی | hossein arabi
m.sc. student, radiation medicine dept., shahid beheshti university, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه شهید بهشتی (Shahid beheshti university)
علیرضا کمالی اصل | alireza kamali asl
assistant professor, nuclear engineering dept., shahid beheshti university, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه شهید بهشتی (Shahid beheshti university)
سید محمودرضا آقامیری | seyed mahmood reza aghamiri
associate professor, nuclear engineering dept., shahid beheshti university, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه شهید بهشتی (Shahid beheshti university)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_7252.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات