این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
Iranian Journal of Medical Physics
، جلد ۶، شماره Issue ۳,۴، صفحات ۵۸-۷۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging
چکیده انگلیسی مقاله
Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle energy window method to correct this cross-contamination. Material and Methods: Using NCAT, a typical software torso phantom was generated. An extremely thin line source of 99mTc activity was placed inside the cardiac region of the phantom and no activity in the other parts. The SimSET Monte Carlo simulator was used to image the phantom in different energy windows. To find the relationship between projections in different energy windows, deconvolution theory was used. We investigated the ability of the suggested functions in three steps: Monte Carlo simulation, phantom experiment and clinical study. In the last step, SPECT images of eleven patients who had angiographic data were acquired in different energy windows. All of these images were compared by determining the contrast between a defect or left ventricle cavity and the myocardium. Results: We found a new 2D kernel which had an exponential pattern with a much higher center. This function was used for modeling 99mTc down scatter distribution from the middle window image. X-ray distribution in the 201Tl window was also modeled as the 99mTc photopeak image convolved by a Gaussian function. Significant improvements in the contrasts of the simultaneous dual 201Tl images were found in each step before and after reconstruction. In comparison with other similar methods, better results were acquired using our suggested functions. Conclusion: Our results showed contrast improvement in thallium images after correction, however, many other parameters should be evaluated for clinical approaches. There are many advantages in simultaneous dual isotope imaging. It halves imaging time and reduces patient waiting time and discomfort. Identical rest/stress registration of images also facilitates physicists’ motion or attenuation corrections and physicians’ image interpretation.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
فراز کلانتری | faraz kalantari
phd student, medical physics dept., faculty of medical sciences, tarbiat modares university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه تربیت مدرس (Tarbiat modares university)
حسین رجبی | hossein rajabi
associate professor, medical physics dept., faculty of medical sciences, tarbiat modares university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه تربیت مدرس (Tarbiat modares university)
ناهید یعقوبی | nahid yaghoobi
assistant professor, nuclear medicine dept., rajaei heart center, iran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
احمد بیطرفان | ahmad bitarafan
assistant professor, nuclear medicine dept., rajaei heart center, iran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_7288.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات