عنوان انگلیسی
Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz
چکیده انگلیسی مقاله
Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accuracy of the internal dosimeter was verified. Dose-area products (DAP) of patients (236 cases) during fluoroscopy and cine acquisition were recorded. Analyzing the data, the average radiation doses to patients for angiography and angioplasty and also for fluoroscopy and cine acquisition were determined. Additionally, the average fluoroscopy time for all patients was estimated. Results: The average DAPs of 23.7 and 91.5 Gycm2 were estimated for angiography and angioplasty respectively. Patient doses including fluoroscopy, cine acquisition and the total dose for angiography were 2, 7.7 and 3.8 times lower than angioplasty procedures respectively. Average fluoroscopy time was 1.9 times lower for angiography compared to angioplasty. Discussion and Conclusion: Fluoroscopy time and patient dose during fluoroscopy were in good agreement with other studies. However, the dose to patients during angioplasty was higher compared to other reports. To reduce patient dose in angioplasty procedures, the use of the lowest available frame rate, smallest field size and retraining of operators and technologists are recommended.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
اصغر مصباحی | asghar mesbahi
assistant professor, medical physics dept., tabriz university of medical sciences, tabriz, iran. radiotherapy physicist of the radiotherapy department of imam hospital, tabriz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
ناصر اصلان آبادی | naser aslanabadi
associate professor, cardiology dept., tabriz university of medical sciences, tabriz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
پریناز محنتی | parinaz mehnati
associate professor, medical physics dept., tabriz university of medical sciences, tabriz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
احمد کشتکار | ahmad keshtkar
associate professor, medical physics dept., tabriz university of medical sciences, tabriz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_7390.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات