این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۵، شماره Issue ۱,۲، صفحات ۹-۲۲

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Determination of Dosimetric Parameters of the Second Model of Pd-103 Seed Manufactured at Agricultural, Medical and Industrial Research School
چکیده انگلیسی مقاله Introduction: The use of low energy isotopes such as 103 Pd in brachytherapy for the treatment of cancers such as prostate, eye, head, neck, breast and cervix is increasing. In this regard, different models of Pd- 103 seeds have been designed and manufactured at the Agricultural, Medical and Industrial Research School (AMIRS) of Atomic Energy Organization of Iran. In this research, the dosimetric parameters of the second model of Pd-103 seed manufactured at AMIRS have been calculated and measured. Materials and Methods: The dosimetric parameters of the second Pd-103 seed manufactured at AMIRS were determined according to TG-43U1 protocol using Monte Carlo calculations (MCNP4C computer code) and measurements performed using TLD-GR200A dosimeters in a Perspex phantom. The parameters include dose rate constant, geometry function, radial dose function, anisotropy function, anisotropy factor and anisotropy constant. Results: It was found that by using MCNP4C code the calculated dose rate constant in water and Perspex was 0.706±0.001 and 0.501±0.001 cGyh -1 U -1 , respectively. Using the calculated geometry function, the radial dose function and the anisotropy function were determined by experimental and theoretical methods in water and Perspex phantom. Also, the calculated value of anisotropy constant in water was equal to 0.88. Discussion and Conclusion: A discrepancy of less than 10% between the calculated and the measured values indicates a reasonable agreement between the simulation and the measurement method. Also, the dosimetric parameters of this seed have been compared to the dosimetric parameters of the first Pd-103 seed manufactured at AMIRS and some other seeds. The obtained results indicate that the seeds manufactured at AMIRS have acceptable dosimetric parameters suitable for brachytherapy applications.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله غلامرضا رییس علی | gholamreza raisali
associate professor, radiation application research school, nuclear science and technology research institute, atomic energy organization of iran, tehran, iran

سازمان اصلی تایید شده: سازمان انرژی اتمی (Atomic energy organization)

مهدی صادقی | mahdi sadeghi
assistant professor, agricultural, medical and industrial research school, nuclear science and technology research institute, atomic energy organization of iran, karaj, iran

سازمان اصلی تایید شده: سازمان انرژی اتمی (Atomic energy organization)

وحیده عطایی نیا | vahideh ataeinia
m. sc. in medical applications of radiation, nuclear engineering dept, faculty of engineering, science and research unit, islamic azad university, tehran, iran

سازمان اصلی تایید شده: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)

ارژنگ شاهور | arjang shahvar
b. sc. in physics, agricultural, medical and industrial research school, nuclear science and technology research institute, atomic energy organization of iran, karaj, iran

سازمان اصلی تایید شده: سازمان انرژی اتمی (Atomic energy organization)

مریم قاسمی ghonchehnazi | maryam ghasemi ghonchehnazi
m. sc. in medical physics, medical physics dept., faculty of medical sciences, isfahan university of medical sciences, isfahan, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)


نشانی اینترنتی http://ijmp.mums.ac.ir/article_7526.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات