این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۵، شماره Issue ۱,۲، صفحات ۴۳-۵۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone
چکیده انگلیسی مقاله
Introduction: The use of mobile communication systems has dramatically increased over the past decade. Although many studies have been performed to determine the effect of radio frequency (RF) but less attention has been paid to the possible biological impact of exposure to extremely low frequency (ELF) components. The objective of this study is two folds. One is to design the equipments needed for the measurement of the ELF fields of two types of GSM900 mobile phone. Secondly, use a protocol suitable for an accurate assessment of the ELF fields. Materials and Methods: First a home-made search coil was provided and calibrated precisely under several experiments. Using Fast Fourier Transform, the power spectrum density of the induced voltage in the search coil was analyzed and the amplitudes of 217 Hz and its harmonics were extracted and then the distribution of magnetic field in the back side of mobile phones was determined. Results: The values of B-field on the back side of the two kinds of GSM mobile phone were different. They were between 50 to 160 µT in Nokia 3310 and 14 to 30 µT in Nokia 8310. Considering the difference between the amplitudes of frequency components at 217 Hz and its harmonics in the two kinds of mobile phone, a range of magnetic flux density at different times in a five day period was measured. Discussion and Conclusion: These findings emphasize the need for considering the distribution of low frequency magnetic field from mobile phone when biological effects of magnetic fields are studied. To determine the intensity windowing effect, one must consider the physical characteristics of the fundamental frequency component wave (217 Hz) and its harmonics produced by the mobile phone similar to the one generated under a real situation.
کلیدواژههای انگلیسی مقاله
217 Hz, Magnetic Fields, Mobile Phones, GSM900
نویسندگان مقاله
مهری کاویانی مقدم | mehri kaviani moghadam
ph.d. student in medical physics, tarbiat modares university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه تربیت مدرس (Tarbiat modares university)
سید محمد جعفر pourmir فیروزآبادی | seyed mohammad jafar pourmir firoozabadi
associate professor, medical physics dept., tarbiat modares university, tehran, iran
سازمان اصلی تایید شده
: دانشگاه تربیت مدرس (Tarbiat modares university)
m lak | m. lak
m.sc. student in biomedical engineering bioelectric , science and research campus, islamic azad university, member of young researchers club, tehran, iran
سازمان اصلی تایید شده
: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)
m جان احمدی | m. janahmadi
professor, physiology and neuroscience research center, shahid beheshti medical sciences university, tehran, iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_7529.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات