این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۴، شماره Issue ۳,۴، صفحات ۱-۱۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Fabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics
چکیده انگلیسی مقاله Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measurement principals of well type chambers were considered and MCNP-4C code as a calculation tool was used. The designed chamber was simulated and the response of the chamber was evaluated. In this investigation, the chamber operational parameters such as operating voltage, leakage current, reproducibility, reference measuring point, recombination and polarization factors as well as response stability for 137Cs, 57Co and 241Am sources were studied. Results: The chamber leakage currents at the operating voltage in comparison to the chamber response for the measurement of the above mentioned sources were negligible. The responses of the fabricated chamber for these sources are reproducible and its reference measurement position for these sources was obtained at 6 cm from the bottom of the chamber. The recombination factor for the well type chamber was negligible and the polarization factor is close to 1. Therefore, these two factors were not considered in the measurements. The reproducibility of the measurements in different intervals shows the stability of the chamber response for each source. Also the results of the chamber current measurement in term of source strength were compared to the response of the simulated chamber for different source positions and energy ranges of the used sources. Discussion and Conclusion: The results show that the measurement of the reference positions for each source in the simulated and fabricated chamber is quite in a good agreement. Regarding the reliable operational properties of the fabricated chamber, this chamber can be used to determine the activities of brachytherapy sources in which the energy ranges are greater than 50 KeV.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله کوروش اربابی | koroush arbabi
ph.d. student in medical physics, agricultural, medical amp;amp; industrial research school amirs , nuclear sciences amp;amp; technology research institute nstri , atomic energy organization of iran aeoi , tehran, iran

سازمان اصلی تایید شده: سازمان انرژی اتمی (Atomic energy organization)

غلامرضا رییس علی | gholamreza raisali
associate professor, nuclear engineering, radiation application research school rars , nstri, aeoi


معصومه دهقانی مقدم | masoomeh dehghani moghadam
m.sc. in nuclear physics, deputy of nuclear research amp;amp; technology, aeoi, tehran, iran


مصطفی غفوری | mostafa ghafoori
m.sc. in nuclear engineering, amirs, nstri, aeoi, tehran, iran


ارژنگ شاهور | arjang shahvar
b.sc. in nuclear physics, amirs, nstri, aeoi, tehran, iran


سعید حمیدی | said hamidi
assistant professor, nuclear physics dept., physics group, basic sciences faculty, arak university, arak, iran

سازمان اصلی تایید شده: دانشگاه اراک (Arak university)


نشانی اینترنتی http://ijmp.mums.ac.ir/article_7546.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات