این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Sciences، جلد ۳۹، شماره ۱، صفحات ۱۱-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
چکیده انگلیسی مقاله Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal children (group 2) were studied. The mean ORA and TXL IOP values were compared with the GAT-IOP values. Regression analyses were used to evaluate the associations between IOP and CCT, corneal hysteresis (CH), and corneal resistance factor (CRF). Bland-Altman plots were used to evaluate the agreement between the tonometers. Results: The mean±standard deviations of the age and male/female ratio were 16.58±5.44 and 15.75±5.04 years and 14/22 and 18/22 in group 1 and group 2, respectively. CCT in group 1 was 651.1±42 and in group 2 was 567.3±32.4. In group 1, the mean TXL (22.4, P=0.004), IOPcc (corneal compensated) (27.8, P=0.005), and IOPg (Goldmann correlated) values (28.1, P< 0.0001) were greater than GAT-IOP (20.6). In group 2, only IOPg value (16.4) was higher than GAT-IOP (14.8, P=0.04). IOP reading of all the tonometers were positively and negatively associated with CRF and CH in the multiple regression analysis, respectively. Conclusion: The TXL had a greater agreement with the GAT, and the ORA overestimated IOP in aphakic glaucoma patients. The ORA and TXL seemed to be affected by CH and CRF.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله محمد رضا رازقی نژاد | mohammad reza razeghinejad
poostchi ophthalmology research center, shiraz university of medical sciences, shiraz, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

رامین صلوتی | ramin salouti
poostchi ophthalmology research center, shiraz university of medical sciences, shiraz, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

محمد رضا خلیلی | mohammad reza khalili
poostchi ophthalmology research center, shiraz university of medical sciences, shiraz, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)


نشانی اینترنتی http://ijms.sums.ac.ir/index.php/IJMS/article/view/427
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات