این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Sciences، جلد ۳۸، شماره ۳، صفحات ۲۴۰-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Evaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
چکیده انگلیسی مقاله Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic technique in C/S. Methods: This study was carried out on 60 parturient patients undergoing elective C/S. A standardized anesthetic technique was applied: induction with Thiopental (4-5 mg/kg) and Succinylcholine (1.5-2 mg/kg) as well as maintenance with O2, N2O, and isoflurane. Electrocardiogram, heart rate, blood pressure, Spo2, end-tidal isoflurane concentration, BIS, and any clinical signs of inadequate depth of anesthesia such as movement, sweating, lacrimation, coughing, and jerking were continuously monitored and recorded at 16 fixed time points during anesthesia. Results: A median BIS of less than 70 (range: 42-68) was obtained on all occasions during surgery; however, at each milestone, at least 20% of the patients had BIS values above 60. Hemodynamic parameters increased significantly in some patients, especially during laryngoscopy and intubation. No patient experienced recall or awareness. Conclusion: The currently used general anesthetic technique in our center appears inadequate in some milestones to reliably produce BIS values less than 60, which are associated with lower risk of awareness. Therefore, with respect to such desirable outcomes as good Apgar and clinical status in neonates, we would recommend the application of this method (if confirmed by further studies) through larger dosages of anesthetic agents.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله سید محمد رضا هادوی | sayed mohammad reza hadavi
anesthesiology and critical care research center, department of anesthesiology, faghihi hospital, shiraz university of medical sciences, shiraz, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

الهه الهیاری | elaheh allahyary
anesthesiology and critical care research center, department of anesthesiology, faghihi hospital, shiraz university of medical sciences, shiraz, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

سامان اسدی | saman asadi
anesthesiology and critical care research center, department of anesthesiology, faghihi hospital, shiraz university of medical sciences, shiraz, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)


نشانی اینترنتی http://ijms.sums.ac.ir/index.php/IJMS/article/view/79
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات