این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 22 آذر 1404
Iranian Journal of Medical Sciences
، جلد ۳۴، شماره ۱، صفحات ۲۹-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Effect of the Type of Hemodialysis Buffer on the QTc Interval in Patients on Chronic Hemodialysis
چکیده انگلیسی مقاله
Background : Identifying the sources of variation in QTc measurements is important for preventing arrhythmias during and after hemodialysis. The present study was designed to determine the correlation between the type of hemodialysis buffer and the changes in QTc interval in patients on chronic hemodialysis. Methods: Fifty-nine patients on chronic hemodialysis who referred in winter 2007 to hemodialysis centers of Ghaem and Hashemi Nejad hospitals, in Mashhad, Iran, were divided into two groups according to their last dialysate buffer: acetate or bicarbonate. Electrocardiography, arterial blood gas parameters, serum K + , Na + , ionized calcium, and albumin levels were measured prior to and after hemodialysis in all patients. Results: All arterial blood gas parameters and serum electrolytes concentrations were increased except K + levels that were significantly decreased with hemodialysis. PCO 2 and QTc intervals were slightly increased in all patients, however this increase was not statistically significant. We found that the type of dialysate affected the QTc interval, HCO 3 , base excess, base excess of extra cellular fluid, and base buffer changes with no effect on ionized calcium, pH, PCO 2 , and serum albumin concentration. QTc interval was prolonged by using bicarbonate and shortened by using acetate dialysate buffer. We found no correlation between the variations of QTc interval and serum electrolytes or arterial blood gas parameters in either group. Conclusion: Bicarbonate buffer use in hemodialysis prolonged QTc interval and acetate buffer shortened it. This effect is independent of serum electrolytes and pH changes during hemodialysis. The effect of bicarbonate buffer is probably due to more tolerability of ultra filtration, more effective edema reduction and augmented body electro-conductivity.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
رضا حکمت | reza hekmat
abddollah بهرامی | abddollah bahrami
مصطفی احمدی | mostafa ahmadi
حسین نظری | hossein nazari
نشانی اینترنتی
http://ijms.sums.ac.ir/index.php/IJMS/article/view/1742
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات