این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Dental Research Journal، جلد ۱۲، شماره ۴، صفحات ۰-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Effect of tightening torque on the marginal adaptation of cementretained retained
چکیده انگلیسی مقاله Background: The fi nal position of the abutment changes with the amount of tightening torque. This could eventually lead to loss of passivity and marginal misfi t of prostheses. The aim of this study was to evaluate the effect of three different tightening torques on the marginal adaptation of 3-unit cement-retained implant-supported fi xed dental prostheses (FDPs). Materials and Methods: Two implants (Straumann) were inserted in an acrylic block so that one of the implants was placed vertically and the other at a 15° vertical angle. A straight abutment and a 15° angulated abutment were connected to the vertically and obliquely installed implants, respectively, so that the two abutments were parallel. Then, 10 cement-retained FDPs were waxed and cast. Abutments were tightened with 10, 20, and 35 Ncm torques, respectively. Following each tightening torque, FDPs were luted on respective abutments with temporary cement. The marginal adaptation of the retainers was evaluated using stereomicroscope. FDPs were then removed from the abutments and were sectioned at the connector sites. The retainers were luted again on their respective abutments. Luting procedures and marginal adaptation measurement were repeated. Data were analyzed by ANOVA and least signifi cant difference tests (α = 0.05). After cutting the FDP connectors, the independent samples t -test was used to compare misfi t values (α = 0.05). Results: Following 10, 20, and 35 Ncm tightening torques, the marginal discrepancy of the retainers of FDPs signifi cantly increased ( P < 0.05). There was no signifi cant difference between the marginal discrepancies of these two retainers ( P > 0.05). The marginal gap values of angulated abutment retainers (ANRs) were signifi cantly higher than those of the straight abutment after cutting the connectors ( P = 0.026). Conclusion: Within the limitations of this study, the marginal misfi t of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfi t of the ANRs was higher than those of the straight abutment retainers. Key Words: Dental implants, fi xed partial denture, implant-supported prosthesis, marginal adaptation, torque
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله جلیل قنبرزاده | jalil ghanbarzadeh


حسین دشتی | hossin dashti


رضا کارآمد | reza karamad


مرضیه علی خاصی | marzieh alikhasi


محمدرضا نخعی | mohammadreza nakhaei



نشانی اینترنتی http://drj.mui.ac.ir/index.php/drj/article/view/1721
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات