این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Dental Research Journal، جلد ۱۱، شماره ۱، صفحات ۰-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations:A scanning electron microscopy evaluation
چکیده انگلیسی مقاله Background: Microleakage is one of the challenging concerns in direct fi lling restorations. Understanding of its related factors is important in clinical practice. The aim of this study was scanning electron microscopy (SEM) evaluation of marginal integrity in three types of tooth-colored restorative materials in class V cavity preparations and the effect of load cycling and polishing time on the microleakage. Materials and Methods: In this in vitro experimental study, class V cavity preparations were prepared on the buccal and lingual surfaces of 60 bovine incisors. The specimens were divided into three groups each containing 20 teeth: group 1: Filtek Z350, Group 2: Fuji IX/G Coat Plus, Group 3: Fuji II LC/GC varnish. In each group, 2 subgroups ( n = 20) were established based on fi nishing time (immediate or delayed by 24 h). All specimens were thermocycled (×2,000, 5-50°C). In each sub groups, half of the teeth were load cycled. Epoxy resin replicas of 24 specimens were evaluated under fi eld emission-SEM and interfacial gaps were measured. All teeth were then immersed in 0.5% basic fuchsin dye for 24 h, sectioned and observed under stereomicroscope. Data were analyzed with Kruskal-Wallis’ test and Mann-Whitney U test and a comparison between incisal and cervical microleakage was made with Wilcoxon test. P < 0.05 was considered as signifi cant. Results: Load cycling and fi lling material had a signifi cant effect on microleakage, but polishing time did not. Cervical microleakage in Z350/load cycle/immediate polish and Fuji IX/load cycle/immediate or delayed polish and Fuji IX/no load cycle/immediate polish were signifi cantly higher than incisal microleakage. Conclusion: It was concluded that the cervical sealing ability of Fuji IX under load cycling was better than Fuji II LC. Under load cycling and immediate polishing Z350 showed better marginal integrity than both Fuji II LC and Fuji IX. The immediate polishing didn’t cause a statistically signifi cant increase in microleakage of evaluated tooth-colored class V restorations. Key Words: Composite resins, dental leakage, dental polishing, glass ionomer cements
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله منصوره میرزایی | mansoreh mirzaie


اسماعیل یاسینی | esmail yasini


حمید کرمانشاه | hamid kermanshah


بهاران رنجبر امیدی | baharan ranjbar omidi



نشانی اینترنتی http://drj.mui.ac.ir/index.php/drj/article/view/1549
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات