این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
Dental Research Journal
، جلد ۹، شماره ۴، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
An analysis of postoperative complications and efficacy of 3-D miniplates in fixation of mandibular fractures
چکیده انگلیسی مقاله
Background: Recently, various modifications in transorally placed miniplates for direct fixation of the mandibular fracture are gaining popularity. The modifications have various advantages like more rigidity, less foreign material, less time in application, etc. Among the various modifications of miniplates, three-dimensional (3-D) plating system is also gaining popularity. Thus, in the present study, we tried to evaluate the efficacy and postoperative complications of 3-D titanium miniplates in the treatment of mandibular fractures. Materials and Methods: A prospective s tudy was conducted on 40 patients with non-comminuted mandibular fractures. They were treated using a 2-mm 3-D titanium miniplate through intraoral approach. All patients were systematically monitored 6 months postoperatively. Outcome parameters like infection, hardware failure, wound dehiscence, sensory disturbance of the inferior alveolar nerve, occlusion, and 3-D plate stability were recorded. The statistical tests used in study were mean, standard deviation, and Chi-square test. P values less than 0.05 were considered significant and values less than 0.001 were considered very highly significant. Results: Two patients had a postoperative infection with no consequences. All patients had normal sensory function 3 months after surgery. Plate fracture had not occurred in any patient. Occlusal was normal and wound dehiscence was not reported. 3-D plate was stable in all the patients. Conclusions: It was seen that 3-D titanium miniplates were effective in the treatment of mandibular fractures and overall complication rates were lesser. In symphysis and parasymphysis regions, 3-D plating system uses lesser foreign material than the conventional miniplates using Champy’s principle. Key Words: 3-D plate, complications, fracture, internal fixation, mandible, miniplates, occlusion
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
sadhasivam gokkulakrishnan | sadhasivam gokkulakrishnan
سانجی سینگ | sanjay singh
اشیش شارما | ashish sharma
اشیش کومار شاهی | ashish kumar shahi
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/1156
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات