این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 22 آذر 1404
Dental Research Journal
، جلد ۴، شماره ۱، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Composite-Dentin Bond Strength of Two Adhesives in Different Conditions
چکیده انگلیسی مقاله
Introduction The purpose of this study was to evaluate the effect of thermo-cycling and curing mode of composites (light and chemical curing) on dentin bond strength of one all-in-one and an one-bottle bonding systems. Methods and Materials Occlusal enamels of eighty caries-free third molars were ground with a model trimmer to create flat surfaces in superficial dentin for bonding, and randomly divided into 4 groups. Teflon molds with 1 mm internal diameter were mounted on the flat surfaces, Prompt L-pop (all-in-one system) (3M-ESPE) and Single-Bond (one-bottle system) (3M-ESPE) were used and re-stored with FiltekZ250 (light-cured composite) (3M-RSPE) and Concise (chemically cured compos-ite) (3M-ESPE) composites. Specimens were stored in 37°c distilled water for 24 hours. 10 speci-mens of each group were thermo-cycled 500 times between 5°c to 55°c. Micro- shear bond strength test was done with 0.5mm/min crosshead speed (Dartec, England). The data were analyzed by ANOVA and Duncan's tests. Results The mean shear bond strengths of two adhesive systems with light-cured composite showed no significant differences with and without thermo-cycling (P< 0.05). Also, there was no significant difference between bond strength of two adhesive systems with light-cured composite (P< 0.05). Use of chemically cured composite reduced the bond strength of Single-Bond signifi-cantly (P< 0.001). There was not any bond between chemically cured composite to dentin, using prompt L-pop. Discussion Thermal cycles, in the range that we used them, did not have any influence on the bond strengths of two mentioned systems. The effect of increasing cycles should be evaluated. Use of chemically cured composite decreases the bond strength of Single-Bond and there was no bond be-tween this kind of composite and Prompt L-pop system. So these systems, especially Prompt L-pop, shouldn't be used with chemically cured composite in routine dental treatments. Key Words Simplified Adhesives, Thermo-cycling, Chemically Cured, Composite Resins.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
p صمیمی | p. samimi
a filsoufi | a. filsoufi
k فتح پور | k. fathpour
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/47
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات