این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 21 آذر 1404
Dental Research Journal
، جلد ۲، شماره ۲، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
An Invitro Study of Micro10 Solution's Capability of Endodontic Hand Instruments Sterilization
چکیده انگلیسی مقاله
Introduction Microorganisms have an essential role in pulpo-periapical pathosis, therefore obtaining a successful treatment has a direct relationship with their elimination. According to previous studies, the most reliable method of sterilization is autoclave ,but in some instances there are limitations for using this method, and we need an alternative .One of the most popular and wide-spread materials in this field is Micro10 solution. The aim of this research is to determine the sterilization effect of Micro10 solution on endodontic hand instruments. Methods 1200 endodontic hand files were selected for this study, (15 groups of 80 files). Each bacterial group was prepared in 0.5 Mc Farland standard concentration (1.5 ×108). Every 5 groups of files were contaminated with one of bacterial samples. Then each group of contaminated files, underwent sterilization process, using one of the following methods: a) Application of autoclave, b)Application of 2% Micro10 solution, in 15 minutes, c) Application of 2% Micro10 solution, in 60 minutes, d) Application of 10% Micro10 solution, in 15 minutes, and e) Application of 10% Micro10 solution, in 60 minutes. Results The results of this study indicated that only in group 1 (autoclave) all of samples were sterile, but in other groups sterility diminished to 82.1% (group2), 83.3% (group 3), 90.8% (group 4), and 93.3% (group 5). Conclusion Only autoclave is a reliable method for obtaining a sterile condition and Micro10 solution at the most is just a good disinfectant, especially in 10 % concentration. Also we concluded that the concentration of Micro10 solution has a direct effect on its killing ability of bacteria, while duration of process (60 minutes versus 15 minutes) has no effect. Key words Sterilization, Micro10 Solution, Disinfectant
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
m براتی | m. barati
a طبیبیان | a. tabibian
m اقبالی | m. eqbali
h باقری | h. bagheri
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/95
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات