Assessment of Radiation Dose to the Lens of the Eye and Thyroid of Patients Undergoing Head and Neck Computed Tomography at Five Hospitals in Mashhad, Iran
چکیده انگلیسی مقاله
Introduction: In recent years, the number of computed tomography (CT) scans, which is a high-dose technique, has increased significantly. Head and neck CT is performed frequently and thyroid, particularly in children, has always been considered a sensitive organ. In recent years, radiobiologists and health physicists have been more concerned about the safety of lenses of the eyes, as cataract is no longer considered a deterministic effect. Material and Methods: In the present study, incurred doses to the thyroid and lens of the eye of 140 patients who underwent common head and neck CT at five hospitals were measured by thermoluminescent dosimeters (TLD-100). The patients were divided into two age groups of pediatrics and adults. TLD chips were placed on the patient's skin surface. For each patient, scan parameters, sex and age were recorded. Exposed TLDs were read by a manual TLD reader. Results: The verage absorbed dose of the thyroid, as well as the lenses of the left and right eyes were 5.89±1.74, 15.84±2.81 and 16.25±2.57, respectively, for the pediatric patients and 5.00±1.17, 17.64±1.69 and 24.41±1.89 for adults. Patient-specific organ doses were influenced by the scanned region, scan protocol and patient's age. Conclusion: In the present study, the mean eye dose was much lower than the 500 mGy threshold recommended by International Commission on Radiological Protection (ICRP) for lens of the eye damage, thus, it appears to be clinically safe. While CT scan remains a crucial tool, further dose reduction can be achieved by controlling different factors affecting patient doses.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Mohammad Taghi Bahreyni Toossi
Medical Physics Department, Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
| Hoda Zare
Mashhad University of Medical Sciences
| Zahra Eslami
M.Sc. Student of Medical Physics, Medical Physics Dept., Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| Shahram Bayani Roodi
Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| Mohammad Daneshdoust
M.Sc. Student of Medical Imaging Technology, Medical Physics Dept., Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| Zarif Saeed
B.Sc. of Radiology, Department of Radiology Technology, Faculty of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| Mahdi Sedighpour
M.Sc. of Medical Engineering, Medical Physics Dept., Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| Nastaran Mohammadian
M.Sc. of Medical Physic, Medical Physics Dept., Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| Mohammad Hashemi
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
| Khani Afsaneh
Reza Radiotherapy Oncology Center, Mashhad, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11284.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-880708.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات