Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
چکیده انگلیسی مقاله
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 cases of questionable pulmonary embolism. Results: Image quality was twice as high as the standard protocol in the 80-kV group (odds ratio=2.08). Main, segmental, and subsegmental arteries showed significantly higher vascular enhancement (P< 0.001) in the 80-kV group. Similarly, the mean number of measurable segmental arteries was significantly greater in the 80-kV group relative to the standard group. On the other hand, the mean of image noise was significantly higher in the 80-kV group in comparison with the 100-kV group (mean: 68.4 vs. 43.1; P< 0.001). Finally, the mean of radiation dose received in the 80-kV group was significantly lower than that in the 100-kV group (mean: 0.94 vs. 2.43 mSv; P< 0.001). Conclusion: Lower radiation dose received and higher image quality, but worse image noise, in the 80-kV group compared to the 100-kV group present acceptable evidence in support of reduction of voltage in cases with the suspicion of pulmonary embolism. In these patients, therefore, it is recommended as a good strategy to be adopted in computed tomography angiography.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Mohammad Davoodi
MD, Department of Radiology, Ahvaz Jondishapur University of Medical Sciences, Khuzestan, Iran
| Soudabeh Belash-Abadi
MD, Ahvaz Jondishapur University of Medical Sciences, Khuzestan, Iran
| Seyed Hossein Aalaei-Andabili
MD, Nikan Health Researchers Institute, Tehran, Iran
| Ali Kabir
MD, PhD, Minimally Invasive Surgery Research Center, Iran University of Medical Sciences, Tehran, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_10553.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-880710.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات