Impact of Silicone gel breast prosthesis on photon beam therapy of recurrence carcinoma post mastectomy
چکیده انگلیسی مقاله
AbstractIntroduction Silicone gel breast implants are used for breast reconstruction post mastectomy. In the event of cancer recurrence, the radiation oncologists are forced to irradiate through the prosthesis device. Due to prosthesis higher atomic number dose perturbations occur during treatment. This study determined the influence of silicone gel thickness on the photon beam distribution. Materials and MethodsA Varian linear accelerator, water phantom (dimensions 30 × 30 × 30 cm3), silicone gel breast prosthesis and Omni-Pro Accept software were used in the study. With the gantry positioned at at a source-to-surface distance (SSD) of 100 cm, the collimators were adjusted to a field size of 10 × 10 cm2 and the 6 MeV photon beam was used. Omni-Pro Accept software was used to plot the percentage depth dose curves and the beam profiles. The results obtained with a Monte Carlo Nuclear Particle (MCNP) Code were validated with the measurement data. The beam profile and percentage depth dose curves were also measured for silicone gel thicknesses (4, 6, 8, 10, 12, 14 and 16 cm) and width 16.5 cm aligned 1 cm below the surface of the water.ResultsThe measured and calculated percentage depth dose (PDD) ratio was 0.03. The measured and calculated beam profiles were 0.5% and 0.9% respectively. For the silicone gel prosthesis, the depth dose values at 0.5 cm below the prosthesis were 2.8%.ConclusionDose perturbations below the breast prosthesis are insignificant, breast prosthesis are safe in the event of carcinoma recurrences.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Ramaesela Letsoalo
Department of Medical Physics, Faculty of Medicine, Sefako Makgatho Health Sciences University, Pretoria, South Africa
| Mpho Sithole
Department of Physics, Faculty of , Sefako Makgatho Health Sciences University, Pretoria, South Africa
| Mpumelelo Nyathi
Department of Medical Physics Sefako Makgatho Health Sciences University SouthAfrica
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_10514.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-880713.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات