این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Occupational Hygiene، جلد ۷، شماره ۴، صفحات ۱۶۶-۱۷۱

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Single-Axis and Three-Axis Probe Magnetic Field Meters in an Occupational Hygiene Study: A Comparative View
چکیده انگلیسی مقاله ORIGINAL ARTICLE Background and Objectives: One type of electromagnetic fields, based on frequency range, is Extremely Low Frequency (ELF) fields. There are lots of reports about measuring ELF- magnetic field (MF) in substations, power plants, cities, near high voltage power lines and etc. This study aimed to compare the difference between measurement of three-axis and single-axis probe MF meters. Methods: ELF-MF was measured by TES-1394 MF tester (three-axis probe) and HI-3604 ELF survey meter (single-axis probe) in selected power planet and the resultant of three MF components (X, Y, and Z) was calculated based on equation. Field measurement was based on IEEE std 644-1994. Result: In the generator building, minimum, maximum, and mean values of the magnetic flux density measured by the three-axis device were greater than those measured by the other two methods. Besides, the maximum value of the resultant method was greater compared to the measurements related to the other two methods, but the means of magnetic flux density by the three-axis device was greater than the resultant and maximum axis value. However, a significant difference was found between the maximum axis value and the results of the three-axis device (P=0.022). Nevertheless, no significant difference was observed between the resultant of the three-axis and the maximum axis (P=0.29) and three-axis device (P=0.21). Conclusion: The best and most reliable way to measure MF is using a device with a three-axis probe and measuring the maximum MF by the singe-axis device cannot be reliable. Moreover, in the absence of a device with a three-axis probe, if there is a single-axis probe, the best we can do is obtaining the resultant from the three directions of the field.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله محمد رضا منظم اسماعیل پور | mohammad reza monazzam esmail pour


حامد جلیلیان | hamed jalilian


کامران نجفی | kamran najafi


سید ابوالفضل ذاکریان | seyed abolfazl zakerian



نشانی اینترنتی http://ijoh.tums.ac.ir/index.php/ijoh/article/view/139
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات