Iranian Journal of Pathology
، جلد ۱۱، شماره ۴، صفحات ۳۶۳-۳۶۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid
چکیده انگلیسی مقاله
Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through refractometer and strip in differentiation of exudates from transudates. Methods: The serum of patients was evaluated for protein, LDH, cholesterol, bilirubin and albumin. The fluid was evaluated for the number of white blood cells, protein, LDH, cholesterol, bilirubin and albumin. Then the fluids were divided into exduate and transudate categories based on Light and Gradient criteria. Finally, the specific gravity of the fluids was measured by refractometer, Erma, Japan and Medi-Test Combi II. The categorized fluids were compared with Gold Standards (final diagnosis) so that the sensitivity and specificity of Light and Gradient criteria in the transudate-exudate differentiation were specified. Results: In comparison with Light criteria, the cut off level of 1022 specific gravity measured by refractometer for pleural effusion has sensitivity, specificity of 92.1%, 68.1%respectively. In evaluation of peritoneal fluid considering cut off point 1023, measured by refractometer has reliable sensitivity 92.4%, specificity 70.4 compared with standard gradient method. Conclusion: Differentiating transudate from exudates by measuring its special gravity by refractometer will have acceptable sensitivity and specificity, and when rapidity is necessary or access to lab equipment is limited, this method could be used.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
علیرضا عبداللهی |
dept. of pathology, imam khomeini hospital complex, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
زهره نوذریان |
dept. of pathology, imam khomeini hospital complex, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
نشانی اینترنتی
http://ijp.iranpath.org/article_21546_e1d7f38b392079e44c9ed2d5f20e89dd.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
1
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات