این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 22 بهمن 1404
Medical Journal of Islamic Republic of Iran
، جلد ۱۶، شماره ۱، صفحات ۲۹-۳۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
SERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)
چکیده انگلیسی مقاله
Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of these characteristics cystatin C is assumed to be a better marker of glomerular filtration rate than other markers. 115 new cases of renal disease aged between 14 and 88 years and 121 healthy subjects, aged between 11 and 78 years were studied. In all of the subjects serum cystatin C and creatinine were determined and creatinine clearance was determined only in patients. Cystatin C was determined by a particle-enhanced turbidimetric assay and creatinine was measured by Jaffe's method. In addition, to assess the diagnostic efficiency of serum cystatin C in comparison to that of serum creatinine and creatinine clearance in predicting changes in GFR, we performed Tc99m - DTPA clearance on 53 subjects including controls and patients. A linear relationship was found between Tc99m - DTPA clearance and 11 serum cystatin C (r= 0.712, p-value < 0.001), l/serum creatinine (r= 0.709, pvalue< 0.001) and creatinine clearance (r= 0.777, p- value < 0.001). Diagnostic accuracy in the identification of reduced GFR measured as area under the receiver-operating characteristic plot was 0.878±0.050 (Mean±SE) for cystatin C, 0.866±0.051 for creatinine and 0.866±0.051 for creatinine clearance. The serum cystatin C reference values (mean±1.96 SD) determined was 0.83 - 0.88 mg/L. A cutoff cystatin C concentration of 0.82 mg/L had 92% sensitivity and 79% specificity for detecting abnormal GFR. There was no significant correlation between cystatin C and age (p- value < 0.219) and weight (p- value < 0.193). This study demonstrates that serum cystatin C has an increased diagnostic accuracy for reduced GFR when compared with serum creatinine and creatinine clearance. Hence, cystatin C seems to be an alternative for the estimation of GFR.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
h وهاب آقایی | h vahhab aghai
the department of physiology, faculty of medicine, tehran university of medical sciences, tehran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
p پاسالار | p pasalar
the department of biochemistry, faculty of medicine, tehran university of medical sciences, tehran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
i نجفی | i najafi
the department of nephrology of dr. shariati hospital, tehran university of medical sciences, tehran, i.r. iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
m کدخدایی | m kadkhodaee
the department of physiology, faculty of medicine, tehran university of medical sciences, tehran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
نشانی اینترنتی
http://mjiri.iums.ac.ir/browse.php?a_code=A-10-298-228&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
1
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات