این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 21 بهمن 1404
Iranian Journal of Public Health
، جلد ۴۸، شماره ۲، صفحات ۳۲۳-۳۳۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Diagnostic Value of Two-Dimensional plus Four-Dimensional Ultrasonography in Fetal Craniocerebral Anomalies
چکیده انگلیسی مقاله
Abstract Background: To assess the clinical value of two-dimensional (2D) plus four-dimensional (4D) ultrasonography in diagnosis of fetal craniocerebral anomalies. Methods: Retrospective analysis was performed on the sonographic features of 83 maternity patients admitted to Northwest Women’s and Children’s Hospital, Xian China from January 2013 to December 2017 diagnosed with suspected fetal anomalies of the brain and skull through 2D and 4D ultrasonography. Results: Fifty six patients were diagnosed with the anomalies by 2D ultrasonography only, 65 patients by 4D ultrasonography only, and 74 patients by 2D plus 4D ultrasonography.76 patients were confirmed to have fetal craniocerebral anomalies after birth or induced labor. Diagnostic accuracies of 2D ultrasound only, 4D ultrasound only, and 2D plus 4D ultrasound were 68.67%, 81.93% and 95.18%, respectively (P< 0.05). The accuracy of 2D plus 4D ultrasound was greater than those of 2D ultrasound only and 4D ultrasound only, and the accuracy of 4D ultrasound only was higher than that of 2D ultrasound only (P< 0.05). The sensitivity of 2D plus 4D ultrasound was greater than those of 2D ultrasound only and 4D ultrasound only (P< 0.05). The specificity of 2D plus 4D ultrasound was greater than those of 2D ultrasound only and 4D ultrasound only (P< 0.05). Conclusion: Combined ultrasonography can better differentiate fetal craniocerebral anomalies, providing early and more accurate information for clinicians as well as maternity patients to make a decision. This clinical practice would be valuable for improving the quality of the newborn population. Keywords:
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Yingjin WANG
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
| Xiaoyuan CHEN
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
| Shujuan ZHONG
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
| Rong ZHANG
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
| Yanyan PAN
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
| Peili AN
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
| Xinru GAO
Medical Ultrasound Centre, Northwest Women’s and Children’s Hospital, Xian 710061, P.R. China
نشانی اینترنتی
http://ijph.tums.ac.ir/index.php/ijph/article/view/16154
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/86/article-86-1354042.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات