International Journal of Radiation Research
، جلد ۸، شماره ۱، صفحات ۱۷-۲۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Relationship between the optimum cut off frequency for Butterworth filter and lung-heart ratio in 99mTc myocardial SPECT
چکیده انگلیسی مقاله
Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc concentration. The cardiac insert was then put into a cylindrical tank which filled with six different 99mTc concentrations as background. Thus, six target background concentrations ratios (T/B) were carried out. The LHR was determined for every SPECT raw image obtained corresponding to each T/B. Then, 130 different combinations of filter parameters from Butterworth filter were utilized to reconstruct each SPECT raw image. The determination of count in myocardium, background, and defect regions of interest (ROI) were performed for every reconstructed image. All the count values were then used to calculate contrast, signal-to-noise ratio (SNR), and defect size. Each criterion was graded (1 to 100) and then summed together to obtain total grade. The optimum cut off frequency for each LHR was determined from the total grade. The relation between optimum cut off frequency for Butterworth filter and LHR was established using linear regression. Results: There were good relationship between the optimum Butterworth cut off frequency and LHR (R2 = 0.864, p < 0.01). The optimal cut off frequency correspond to the change in LHR can be expressed by the equation: Optimum cut off frequency = 0.715*LHR + 0.227. Conclusion: This study suggests that the optimum cut off frequency for Butterworth filter should be determined by referring to LHR in each patient study. Iran. J. Radiat. Res., 2010 8 (1): 17-24
کلیدواژههای انگلیسی مقاله
99mTc myocardial SPECT, filtering, lungheart ratio.
نویسندگان مقاله
محمدنقی salihin یوسف | m n salihin yusoff
school of health science, university sains malaysia, kelantan, malaysia
a ذکریا | a. zakaria
department of nuclear medicine, radiotherapy and oncology, hospital universiti sains malaysia, kelantan, malaysia
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-346&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات