این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 1 اسفند 1404
International Journal of Radiation Research
، جلد ۶، شماره ۱، صفحات ۵۱-۵۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Preparation of prostate specific antigen standards for immunoradiometric assay
چکیده انگلیسی مقاله
Background: Immunoradiometric assay is one of the most common and precise methods for determination of prostate specific antigen (PSA) in clinical laboratories. Usual use of human serum in routine assays has many disadvantages such as easy contamination and precipitation, instability and unavailability. Thus in order to avoid these problems the artificial matrix was used which acts similar to human serum. Materials and Methods: In order to design immunoradiometric assay for prostate specific antigen, series of standards in different concentrations were needed for special artificial matrix preparation. The influence of artificial matrix in standards was studied to determine prostate specific antigen in comparison with human serum. Some different factors, such as the amount of non-specific bonding (NSB), precision, and accuracy, conditions of storage and stability of these standards prepared by artificial matrix were investigated. Results: The most appropriate artificial matrix (Tris-glycine (25.0 mmol/L) + NaCl (75.0 mmol/L) + Tris (12.5 mmol/L) +Triton X- 100 (0.5 ml/L) + HSA (1.2 g/L) + Urea (0.5 mol/L)) for preparing the standards was selected in comparison with human serum (HSA) and a commercial kit standards. HSA and Urea concentration have more critical influences on the properties of the standards. The amount of NSB of the selected matrix was the lowest one, so the selected matrix was the most suitable for preparing the standards. The results show the optimum condition of storage duration of our standards for one year was in refrigerator (2-8°C). It was observed that preparation of standards with selected matrix had acceptable accuracy and precision. Conclusion: According to the results, standards which were prepared with this matrix had suitable and appropriate properties and it could be utilized to prepare PSA standards in immunoradiometric assay. Iran. J. Radiat. Res., 2008 6 (1): 51-58
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
h فروتن | h. foroutan
radioisotope department, nuclear science research school, nuclear science and technology institute, atomic energy organization of iran, tehran, iran
سازمان اصلی تایید شده
: سازمان انرژی اتمی (Atomic energy organization)
r نجفی | r. najafi
radioisotope department, nuclear science research school, nuclear science and technology institute, atomic energy organization of iran, tehran, iran
سازمان اصلی تایید شده
: سازمان انرژی اتمی (Atomic energy organization)
محمدحسین بابایی | m h babaei
radioisotope department, nuclear science research school, nuclear science and technology institute, atomic energy organization of iran, tehran, iran
سازمان اصلی تایید شده
: سازمان انرژی اتمی (Atomic energy organization)
m شفیعی | m. shafii
radioisotope department, nuclear science research school, nuclear science and technology institute, atomic energy organization of iran, tehran, iran
سازمان اصلی تایید شده
: سازمان انرژی اتمی (Atomic energy organization)
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-272&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات