این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 28 بهمن 1404
Dental Research Journal
، جلد ۱۴، شماره ۴، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparison of microleakage of Scotchbond™ Universal Adhesive with methacrylate resin in Class V restorations by two methods: Swept source optical coherence tomography and dye penetration
چکیده انگلیسی مقاله
Background: One of the most important factors in restoration failure is microleakage at the restoration interface. Furthermore, a new generation of bonding, Scotchbond Universal (multi‑mode adhesive), has been introduced to facilitate the bonding steps. The aim of this study was to compare the microleakage of Class V cavities restored using Scotchbond™ Universal with Scotchbond Multi‑Purpose in two procedures. Materials and Methods: Eighteen freshly extracted human molars were used in this study. Thirty‑six standardized Class V cavities were prepared on the buccal and lingual surfaces. The teeth were divided into three groups: (1) Group A: Scotchbond Universal with "self‑etching" procedure and nanohybrid composite Filtek Z350. (2) Group B: Scotchbond Universal with "total etching" procedure and Filtek Z350. (3) Group C: Scotchbond Multi‑Purpose and Filtek Z350. Microleakage at enamel and dentinal margins was evaluated after thermocycling under 5000 cycles by two methods of microleakage assay: swept source optical coherence tomography (OCT) and dye penetration. Wilcoxon's signed‑rank test and Kruskal–Wallis test were used to analyze microleakage. Results: In silver nitrate dye penetration method, group A exhibited the minimum microleakage at dentin margins and group C exhibited the minimum microleakage at enamel margins (P < 0.05). Furthermore, in OCT method, group C demonstrated the minimum microleakage at enamel margins (P = 0.047), with no difference in the microleakage rate at dentin margins. Conclusion: Scotchbond Universal with "self‑etching" procedure at dentin margin exhibited more acceptable performance compared to the Scotchbond Multi‑Purpose with the two methods. Key Words: Microleakage, optical coherence tomography, universal adhesive
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Hamid Kermanshah
| Hossein Khorsandian
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/1897
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/171/article-171-1956151.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات