این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 3 اسفند 1404
International Journal of Radiation Research
، جلد ۱۹، شماره ۴، صفحات ۹۶۳-۹۷۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Estimating the radiation surface dose and measuring the dose area product to provide the diagnostic reference level in panoramic radiography
چکیده انگلیسی مقاله
Background: Panoramic radiography is one of the common dental imaging procedures using ionizing radiation. It is necessary to control the level of exposure and use the optimized levels. So, the current work aimed to estimate the surface absorbed doses of critical organ regions, namely thyroid and parotid glands. Moreover, dose area product (DAP) values were measured and a local DRL was then established for panoramic radiography. Materials and Methods: The data from 201 patients including 141 adults and 60 children (5-10 years) were used for this cross-sectional study. Seven panoramic radiography systems were selected from 6 radiology clinics in Yazd province. For each patient, 12 thermoluminescence dosimeters (TLD GR-200) were used to obtain the surface absorbed dose in both the thyroid and parotid gland regions. The DRL values were calculated using DAP values in terms of the ICRP recommendation. Results: The mean and standard deviation (SD) of thyroid and parotid glands' surface absorbed doses were equal to 60.6±3.7 and 290±12.4 µGy in the adult group, respectively. In the children group, these values were 40.7±2 and 189.3±11.5 µGy, respectively. Moreover, the local DRL values were obtained as 99.7 and 73.4 mGy.cm2 for the adults and children groups, respectively. Conclusion: The higher surface absorbed dose values in the adult group can be related to the use of higher radiation parameters. The local DRL proposed for the adult and pediatric groups in the current study was relatively lower than those established by other reports, which seemed acceptable for panoramic radiography in Yazd, Iran.
کلیدواژههای انگلیسی مقاله
Panoramic radiography, surface dose, dose area aroduct, diagnostic reference level.
نویسندگان مقاله
| H. Zamani
Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| A.A. Parach
Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| S.H. Razavi
Department of Oral and Maxillofacial Radiology, Faculty of Density, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| M. Shabani
Radiotherapy Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| Gh. Ataei
Department of Radiology Technology, Faculty of Paramedical Sciences, Babol University of Medical Science, Babol, Iran
| M.H. Zare
Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-1-888&slc_lang=en&sid=1
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات