این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 26 بهمن 1404
International Journal of Pediatrics
، جلد ۹، شماره ۱۲، صفحات ۱۵۱۰۹-۱۵۱۱۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Doppler Phonolyser in Comparison to Conventional Statoscope in Detecting and Interpreting Abnormal heart Murmurs in Congenital and Structural Heart Defects
چکیده انگلیسی مقاله
Background: Echocardiography currently represents a significant proportion of cardiac medical expenditure, while many researchers believe that it would be wise to limit the use of this technique, through the enhancement of diagnosis techniques contributing to clinical auscultation. Hence, this study was conducted to evaluate the efficiency of detection of the newly invented Doppler Phonolyser Machine (DPM) compared to the findings by the conventional stethoscope in detecting heart murmurs.Methods: In a cross-sectional study, a total of 112 patients referred to the pediatric cardiology clinic were enrolled between Jan. 2017 and Jan. 2018. In step one, the patients were initially examined by a pediatric cardiologist, and then in step two, they were randomly divided into two groups (A and B) and were blindly re-examined by a 2nd-year pediatric resident. In Group A (Statoscope group), heart auscultation was performed using only a conventional Statoscope whereas, in Group B (Statoscope + DPM), heart sounds were detected and analyzed using a stethoscope and DPM. In the third step, the diagnostic results made by the pediatric cardiologist and the pediatric resident in groups A and B were compared with the final diagnostic echocardiography made by a pediatric cardiologist.Results: Heart murmurs as one of the most common reasons for cardiologist referrals comprise about 65% of referrals to pediatric cardiologists. There was only a moderate correlation between a stethoscope and echocardiography to identify cardiac abnormality based on heart murmurs (56%), while there was a significant correlation between the diagnoses made by Doppler Phonolyser accompanied with the conventional statoscope when compared with the echocardiography results (٪85).Conclusion: Doppler Phonolyser is an innovative smart machine that could efficiently detect and analyze abnormal heart sounds and might play a key role in more accurate and earlier diagnosis of congenital and structural heart defects by general physicians and non-cardiologist specialists, and may potentially reduce the cost of treatment as well as anxiety of the patient's family.
کلیدواژههای انگلیسی مقاله
Congenital Heart Defect, Heart, Murmur
نویسندگان مقاله
| Behzad Alizadeh
Pediatric and Congenital Cardiology division, Pediatric Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
| Saeed Aminimoghadam
Faculty of Medicine, Mashhad University of Medical Sciences
| Mohammadreza Naghibi
Pediatric and Congenital Cardiology division, Pediatric Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
نشانی اینترنتی
https://ijp.mums.ac.ir/article_19087.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات