این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 25 بهمن 1404
International Journal of Pediatrics
، جلد ۹، شماره ۴، صفحات ۱۳۴۳۷-۱۳۴۴۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Volume CT Dose Index (CTDIvol) and Dose Length Product (DLP) in Routine CT scan Protocols among Children under 15 Years of Age Admitted to Imam Khomeini Hospital in Ahvaz, Iran, during 2019
چکیده انگلیسی مقاله
Background The computed tomography (CT) scan is a valuable tool in the diagnosis of various diseases, but the absorbed dose causes concern, especially for children. The present study aimed to evaluate the absorbed dose of volume CT dose index (CTDIvol) and dose length product (DLP) in routine CT scan protocols in children under 15 years of age admitted to Imam Khomeini Hospital of Ahvaz, Iran. Materials and Methods The present descriptive-analytical epidemiological study was carried out on children under 15 years of age admitted to Imam Khomeini Hospital of Ahvaz during the first 6 months of 2019. CTDIvol and DLP values were measured using a pencil ionization chamber. Universal dosimeter fire ware 2, 20, and single scan standard phantoms were done on children in a single scan for several routine CT scan protocols. Data were analyzed using SPSS software version 16.0. Results Significantly different (P < 0.05) CTDIvol values were obtained for head, chest, and pelvis (2.14 ± 0.93, 0.93 ± 0.07, and 1.20 ± 0.53, respectively). The obtained DLP values for head, chest, and pelvis (28.46 ± 0.93, 23.91 ± 2.26, and 38.14 ±2.52, respectively) were significantly different (P < 0.05). Mean CTDIvol and DLP values calculated for head, chest, and pelvic protocols were significantly different by month. Conclusion The mean CTDIvol and DLP values for the head, chest, and pelvic protocols, which are within the allowable range and will not be associated with the risks mentioned in this test on children, are less than the values suggested by various guidelines and other studies.
کلیدواژههای انگلیسی مقاله
CT Scan, Child, CTDIvol and DLP
نویسندگان مقاله
| Mohammad Ghasem Hanafi
Department of Radiology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
| Maryam Farasat
Department of Radiology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
| Mohsen Cheki
Department of Medical Imaging and Radiation Sciences, Faculty of Paramedicine, AhvazJundishapur University of Medical Sciences, Ahvaz, Iran.
| Hoda Pakzadi
Department of Radiology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
نشانی اینترنتی
https://ijp.mums.ac.ir/article_17428.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات