چکیده انگلیسی مقاله
Background: Auditing the treatment planning system (TPS) software for a radiotherapy unit is of paramount importance in any radiation therapy department. A Plexiglas phantom was proposed to measure the ionization of 60 Co high dose rate (HDR) source and compare dose points in the planning system for auditing and verifying TPS. Methods: Auditing was performed using a Plexiglas phantom in an end-to-end test, and relative dose points were detected by a farmer-type ionization chamber and compared with the relative dose of similar points in TPS. The audit results were determined as pass optimal level (< 3.3%), pass action level (between 3.3% and 5%), and out of tolerance (>5%). Results: The comparison of the collected data revealed that 80% of the measured values were ?5% in the pass level, and 20% of the points were out of tolerance (between 5% and 6.99%). Conclusion: This study documented the appropriateness of the dosimetry audit test and this phantom design for the HDR brachytherapy TPS.
کلیدواژههای انگلیسی مقاله
Audit, brachytherapy, dosimetry, Plexiglas phantom, radiotherapy
نویسندگان مقاله
| Mohammad Javad Tahmasebi Birgani
Department of Medical Physics, Medicine School, Golestan Hospital, Ahvaz Jundishapur University of Medical Science, Ahvaz, Iran
| Hadis Khorshidsavar
Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Science; Department of Radiation Oncology, Medicine School, Golestan Hospital, Ahvaz Jundishapur University of Medical Science, Ahvaz, Iran
| Ali Bagheri
Department of Medical Physics, Medicine School, Golestan Hospital, Ahvaz Jundishapur University of Medical Science, Ahvaz, Iran
| Amir Danyaei
Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Science, Ahvaz; Department of Medical Physics, School of Medicine, Iran University of Medical Science, Tehran, Iran
| Neda Abdalvand
نشانی اینترنتی
http://jmss.mui.ac.ir/index.php/jmss/article/view/615
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Articles
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات