این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Pediatrics، جلد ۱۰، شماره ۴، صفحات ۱۵۷۵۵-۱۵۷۷۱

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Estimation of Effective Doses and Lifetime Risk of Exposure-induced Cancer Death in Pediatric CT Scans
چکیده انگلیسی مقاله Background: The increasing frequency of computed tomography (CT) scans for a range of purposes, particularly pediatrics, has raised concerns regarding the population's radiation exposure and subsequent chances of cancers. This study aimed to estimate the effective doses of pediatrics radiation and induced cancer risks from five most common CT scan procedures in Yazd Province, Iran.Methods: Data of pediatric patients from four age groups of ≤1, 1-5, 5-10, and 10-15 years old were retrospectively collected from 6 educational institutions located in diverse areas of Yazd Province. For each participant, the effective doses and REID (risk of exposure-induced death) rate were estimated by Impact Dose and PCXMC software, respectively. Then, the findings were reported by categorizing the patients regarding their effective diameter.Results: The effective doses and REID values did not show any significant differences among the studied age groups. The highest mean of effective dose was recorded for the scan of abdomen-pelvis (average ± standard deviation, 5.24±3.19 mSv) followed by chest (3.76±2.28 mSv), brain (1.25±1.07 mSv), and sinus (0.65±0.4 mSv) examinations. The highest REID was documented for chest scan (490±314 excess deaths in one million scans) followed by abdomen-pelvis procedure (404±280).Conclusion: The radiation doses delivered to the pediatric patients and the associated fatal cancer risk with common CT procedures were comparably in the same range of the previous studies. Our findings can represent an estimation of the radiation-induced risks of CT scans and can be used for extending the knowledge of clinicians and researchers.
کلیدواژه‌های انگلیسی مقاله Pediatrics, CT scan, Effective Dose, Cancer Risk, Impact Dose, PCXMC Software

نویسندگان مقاله | Elham Razavi
Medical Physics Department, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran.


| Mohammad Hossein Zare
Medical Physics Department, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran.


| Hamed Zamani
Medical Physics Department, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran.


| Hamidreza Masjedi
Medical Physics Department, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran.


| Saman Dalvand
Medical Physics Department, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran


| Seid Kazem Razavi-Ratki
Medical Physics Department, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran.


| Reza Omidi
Medical Physics Department, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran.


| Maryam Hazbavi
Department of Radiation Therapy, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran



نشانی اینترنتی https://ijp.mums.ac.ir/article_19313.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده original article
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات