این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 24 بهمن 1404
Iranian Journal of Nuclear Medicine
، جلد ۳۱، شماره ۲، صفحات ۱۱۹-۱۲۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A Monte Carlo study on quantification of scattering and edge penetration in a breast-dedicated SPECT scanner with lofthole collimation
چکیده انگلیسی مقاله
Introduction: Quantitative accuracy in SPECT is mainly affected by collimator penetration and scattering, particularly for high-energy imaging. Lofthole collimation offers superior performance in terms of penetration and scattering.Methods: In this research, the GATE Monte Carlo simulator was exploited to calculate edge penetration and scattering in the lofthole collimator using an in-air and in-phantom point source of Tc-99m and I-123. The performance of the lofthole was then compared to that of a pinhole. Both lofthole and pinhole collimators were assumed to have the same geometry including an aperture diameter of 3.04 mm and an opening angle of 75°. Furthermore, the angular distribution of the scattering and penetration were investigated for a multi-lofthole collimator.Results: The results show that penetration, scattering, and sensitivity are all a function of the photon energy. The penetration and scattering of the pinhole are about 4% higher than that of the lofthole collimator, for Tc-99m SPECT. Compared to the Tc-99m, I-123 SPECT suffers from approximately 1.5- and 1.42-fold higher penetration and scatter fractions, respectively, for lofthole aperture. Moreover, the lofthole collimator presents a higher sensitivity compared with the pinhole (0.030 versus 0.023 for the Tc-99m SPECT). In addition, the findings exhibit a reduction in sensitivity by increasing the photon incidence angle. Both scattering and penetration fractions illustrate a decreasing trend across the angle of incidence.Conclusion: Compared to pinhole, the lofthole offers superior performance in terms of scattering and penetration for both low- and high-energy SPECT imaging.
کلیدواژههای انگلیسی مقاله
Penetration, Scattering, SPECT, Collimator, Monte Carlo Simulation, Lofthole
نویسندگان مقاله
Maryam Saed |
Department of Physics, Faculty of Science, University of Guilan, Rasht, Iran
Alireza Sadremomtaz |
Department of Physics, Faculty of Science, University of Guilan, Rasht, Iran
Hojjat Mahani |
Radiation Applications Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
نشانی اینترنتی
http://irjnm.tums.ac.ir/article_40081_773efbe7f8dc71ba053ca04b8813bc72.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات