این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 24 بهمن 1404
Iranian Journal of Nuclear Medicine
، جلد ۱۸، شماره ۱، صفحات ۳۲-۳۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Depth dose calculation of Holmium-166 for different shape source by VARSKIN3 code
چکیده انگلیسی مقاله
Introduction: Using beta emitter radionuclide is a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. The aim of this research is to evaluate the tissue response to beta rays of 166Ho and determine the feasibility of beta emitting radionuclide for treatment of skin cancers. Methods: In this work, we have calculated depth dose distribution of 166Ho using Varskin3 code. The code has been run for various input parameters to calculate absorbed depth dose for different shape of source. Results: Absorbed depth dose variation has been calculated for166Ho beta emitter, in different shape of sources such as slab, spherical, cylindrical and 2-D disk shapes. Comparison of the result for different shape sources has been presented. Conclusion: The result shows that 2-D disk source induces damage to skin cells more than other shape of sources. These computational and Lee et al. experimental results are shown that 166Ho radionuclide treatment is very useful for skin cancer therapy. One of advantages of using 166Ho radionuclide is that no adverse effect on underlying bone and soft tissue due to the physical characteristics of beta rays, high linear energy transfer or rapid depth dose fall off is observed.
کلیدواژههای انگلیسی مقاله
Holmium-166,Varskin3 code,Skin cancer,Source shape
نویسندگان مقاله
علی اصغر مولوی | ali asghar
physics department, school of sciences, sabzevar tarbiat moallem university, sabzevar, iran ictp, tril, trieste, italy
اعظم افضلی فر |
physics department, school of sciences, sabzevar tarbiat moallem university, sabzevar, iran
ناصر افضلی فر |
physics department, school of sciences, imam khomeini university, sabzevar, iran
احسان کاشانی |
vasei hospital, sabzevar medical university, sabzevar, iran
نشانی اینترنتی
http://irjnm.tums.ac.ir/article_548_09b3988a3c7d18b7e28702daf65c3ad9.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات