Iranian Journal of Nuclear Medicine، جلد ۱۷، شماره ۲، صفحات ۲۶-۳۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
چکیده انگلیسی مقاله Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective basis. In this study we evaluate and compare the performance of 4 Commercial GE PET/CT cameras, the (i) BGO-based Discovery LS PET/CT (DLS), (ii) the BGO-based Discovery ST PET/CT (DST), (iii) the BGO-based Discovery STE PET/CT (DSTE) and finally (iv) the LYSO-based Discovery RX PET/CT (DRX) scanner using the Geant4 Application for Tomographic Emission (GATE). GATE is an open source Monte Carlo simulation platform developed for PET and SPECT studies and is supported by the OpenGATE collaboration. In accordance with the National Electrical Manufactures Association (NEMA) NU 2-2001 protocols, the validation of models is carried out against actual published measurements and the performance comparison is done for sensitivity, scatter fraction and count rate performance, showing very similar performance compared with published results, thus enabling investigations to better model system performance (e.g. resolution degradation) within the reconstruction task.. The simulated results demonstrate highest sensitivity performance with the DST (though with the highest scatter fraction), and highest NECR performance for the LYSO-based DRX, The results also show that DRX, DLS and DSTE PET/CT cameras have nearly the same amount of scatter fraction.
کلیدواژه‌های انگلیسی مقاله Positron emission tomography (PET),Scanner performance,Gate

نویسندگان مقاله پرهام گرامی فر |
faculty of nuclear engineering and physics, amir kabir university of technology, tehran, iran research institute for nuclear medicine, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

محمدرضا ay | mohammad reza
department of medical physics and biomedical engineering research center for science and technology in medicine research institute for nuclear medicine, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

مجتبی شمسایی زفرقندی | shamsaie zafarghandi
faculty of nuclear engineering and physics, amir kabir university of technology tehran, iran

ژورژ loudos |
department of medical instruments technology, technological educational institute, athens, greece

آرمان rahmim |
department of radiology, school of medicine, johns hopkins university, baltimore, usa.


نشانی اینترنتی http://irjnm.tums.ac.ir/article_533_198e4e903a29769bf2ad22e9651c506a.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده