این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 27 بهمن 1404
Iranian Journal of Nuclear Medicine
، جلد ۱۷، شماره ۲، صفحات ۴۲-۴۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
چکیده انگلیسی مقاله
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-energy technique with only a single energy CT scan. The implementation was done by CT scans of RANDO phantom at tube voltages of 80 kVP and 140 kVP. The acquired data was used to obtain conversion curves (which scale CT numbers at different kVP to each other), in three regions including lung tissue (HU
کلیدواژههای انگلیسی مقاله
PET/CT,Dual energy CT,Attenuation correction
نویسندگان مقاله
بهنوش تیموریان |
faculty of nuclear engineering and physics, amir kabir university of technology research center for science and technology in medicine, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
محمدرضا ay | mohammad reza
research center for science and technology in medicine department of medical physics and biomedical engineering research institute for nuclear medicine, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
مجتبی شمسایی ظفرقندی | shamsaei zafarghandi
faculty of nuclear engineering and physics, amir kabir university of technology, tehran, iran
حسین قدیری |
research center for science and technology in medicine, tehran university of medical sciences, tehran, iran department of medical physics, school of medicine, iran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
نشانی اینترنتی
http://irjnm.tums.ac.ir/article_537_f2deff4f6e7ab84737130d520c642cd8.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات