این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 23 بهمن 1404
The Journal of Tehran University Heart Center
، جلد ۸، شماره ۴، صفحات ۱۹۲-۱۹۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Long-Term Follow-up of Patent Ductus Arteriosus Closure with the Amplatzer Duct Occluder in Children
چکیده انگلیسی مقاله
Background: T ranscatheter closure of patent ductus arteriosus (PDA) has become an alternative treatment to surgery. We evaluated the long-term results of the transcatheter closure of PDA with the Amplatzer Duct Occluder (ADO) in children. Methods: Between May 2004 and October 2012, 138 children with PDA (43 males and 95 females) underwent transcatheter PDA closure. Clinical, electrocardiographic, echocardiographic, and hemodynamic data were assessed pre and postprocedurally and at follow-up. Results: The mean age of the patients at procedure was 3.53 ± 2.43 years (range = 1.1 to 9.5 years), mean weight was1 1.9±4.6 kg (range = 6 to 29 kg), median pulmonary end diameter of the PDA was 5 mm (range = 4 to 15 mm), and median diameter of the ADO was 8 mm (range = 6 to 16 mm). The mean follow-up time was 43.4 ± 23.5 months (range = 13.5 to98 months).The devices were successfully deployed in 136 (98.5%) patients. Device embolization occurred in 2 patients, immediately in one patient and during the first postprocedural night in the other patient. The first patient had percutaneous device retrieval, followed by implantation of a larger device. The second patient had surgical device removal and PDA ligation. Immediately after device implantation, trivial to mild residual shunts were detected in 112 (80%) patients; all the shunts, however, disappeared 24 hours after the procedure. One patient had left pulmonary artery stenosis with a gradient of 25 mm Hg at 24 hours', 40 mmHg at one month's, and 64 mmHg at 6 months' follow-up. There were no cases of late embolization, aortic obstruction, late hemolysis, infective endocarditis, or death. Conclusion: Transcatheter PDA closure with the ADO was safe and effective, with a high success rate at long-term follow-up.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
مصطفی بهجتی اردکانی | mostafa behjati ardakani
yazd cardiovascular research center, shahid sadoughi university of medical sciences, yazd, iran.
محمدامین بهجتی اردکانی | mohammadamin behjati ardakani
baqiyatallah university of medical sciences, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)
محمدحسن عبداللهی | mohammadhassan abdollahi
yazd cardiovascular research center, shahid sadoughi university of medical sciences, yazd, iran.
نشانی اینترنتی
http://jthc.tums.ac.ir/index.php/jthc/article/view/309
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات