این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 24 خرداد 1405
Iranian Journal of Medical Physics
، جلد ۲۲، شماره ۶، صفحات ۳۹۵-۴۰۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Patient-Specific Dosimetric Validation of Pelvic IMRT and VMAT Plans Using a Custom-designed Female Pelvic Phantom and Arc-CHECK QA System
چکیده انگلیسی مقاله
Introduction: To ensure the accuracy of advanced radiotherapy techniques in the therapy of female pelvic malignancies using radiotherapy, comprehensive quality assurance protocols and patient-specific dosimetry was performed using a custom-designed female pelvic (CDFP) phantom and Arc-CHECK.Material and Methods: Volumetric modulated arc therapy (VMAT) and Intensity modulated radiation therapy (IMRT) plans originally developed for patients with cervical cancer were transferred to the CDFP phantom and Arc-CHECK. The doses for patient-specific quality assurance (PSQA) of advanced techniques were calculated using different algorithms in treatment planning system (TPS). To acquire dose measurements, a 0.600 cc ion chamber, Sun Nuclear 125c (SNC125c) and a pinpoint 0.015 cc chamber were employed. The percentage deviation between the computed and administered dose was calculated. Results: Percentage discrepancies between planned and administered doses were analyzed. The maximum percentage deviation, mean ± standard deviation(SD) differences for 0.6 cc ion chamber and a pin-point 0.015 cc chamber were found to be -3.6%, -0.89% ± 1.59 and 3.51%, 1.10% ± 1.31 for the IMRT treatment technique and -3.32%, -0.84% ± 1.53 and 3.6%, 1.25% ± 1.34 for the VMAT treatment technique using AAA algorithms using 6MV beam for CDFP phantom respectively. The maximum of percentage deviation, mean ± SD differences for 0.6 cc ion chamber and a SNC125c chamber were found to be -3.40%, -0.273% ± 2.161 and 3.107%, -0.028% ± 2.046 for CDFP phantom and -2.72%, -0.35% ± 1.41 and 2.74%, 0.197% ± 1.50 for Arc-CHECK using VMAT treatment technique using 6MV beam and Monte Carlo algorithm respectively.Conclusion: The inherent properties of anthropomorphic phantoms like the CDFP, such an anatomical fidelity and tissue equivalence, make them extremely useful in the quality assurance radiotherapy-programs. Their application increases the accuracy of dosimetric validation and therefore, these phantoms are applicable in the use of high-accuracy treatment modalities such as IMRT and VMAT
کلیدواژههای انگلیسی مقاله
CDFP Arc, CHECK Algorithms Phantom Quality Assurance
نویسندگان مقاله
| Ajay Katake
Department of Physics, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Phagwara, Punjab 144411, India
| Lalit Kumar
Department of Radiation Oncology, Max Superspeciality Hospital, Saket, Delhi, India
| Hetvi Usadadiya
Department of Radiation Oncology, N M Virani Wockhardt Hospital, Rajkot, Gujrat, India
| Kruti Haraniya
Department of Radiation Oncology, Sir Sayajirao General Hospital, Vadodara, Gujrat
| Deepak Basandrai
Dept. of Physics, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Phagwara, Punjab 144411, India
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_27447.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات