این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Medical Journal of Islamic Republic of Iran، جلد ۲۶، شماره ۳، صفحات ۱۰۳-۱۰۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Parathyroid adenoma Localization
چکیده انگلیسی مقاله  Background: Bilateral neck exploration is the gold standard for parathyroid adenoma localization in primary hyperparathyroidism. But surgeons do not have adequate experience for accurate surgical exploration and new methods are developed for surgery like unilateral exploration and minimally invasive surgery, thus, preoperative localization could reduces time and stress in surgical performance. Method: 80 patients with documented primary hyperparathyroidism and with raised serum calcium and parathyroid hormone (PTH) were selected. The results of ultrasonographic localization for each patient were compared with findings of surgery and 99m technetium sestamibi scintigraphy. Also variables such as preoperative serum calcium, PTH level and adenoma weight were compared between patients who had localized and nonlocalized adenoma with ultrasonography or Sestamibi scan. The data was compared with student’s t-test. Results: In a prospective diagnostic tests’ accuracy, 80 patients with primary hyperparathyroidism were enrolled. Ultrasonography images detected enlarged parathyroid glands in 61 of 80 patients (76.3%) with sensitivity of 83.5% and positive predictive value (PPV) of 89.7%. Sestamibi scintigraphy detected adenoma in 63 patients (78.8%) with sensitivity of 85% and PPV of 91.3%. There was no significant deference between ultrasonography and scintigraphy in localization of adenomas. Both ultrasonography and scintigraphy used for determining localization, and they located 73 adenomas (91.3%) with sensitivity of 97.3% and PPV of 93.5%. Conclusion: Ultrasonography as an accurate method for localization of enlarged parathyroid glands in primary hyperparathyroidism, is comparable in overall utility with sestamibi scintigraphy. This study suggests a strategy for initial testing with one method, followed by the alternate imaging test if the first test happen to be negative.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله شیرزاد نصیری | shirzad nasiri
tehran university of medical sciences, tehran, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

احمدرضا سروش | ahmadreza soroush
tehran university of medical sciences, tehran, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

امیر پژمان هاشمی | amir pejman hashemi
tehran university of medical sciences, tehran, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

انوشیروان هدایت | anushiravan hedayat
tehran university of medical sciences, tehran, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

کیانوش دنبلی | kianoush donboli
tehran university of medical sciences, tehran, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

فرهاد مهرخانی | farhad mehrkhani
tehran university of medical sciences, tehran, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)


نشانی اینترنتی http://mjiri.iums.ac.ir/browse.php?a_code=A-10-1-313&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده 1
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات