این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 23 بهمن 1404
Medical Journal of Islamic Republic of Iran
، جلد ۳۰، شماره ۱، صفحات ۲۶۶-۲۷۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods
چکیده انگلیسی مقاله
Background: Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting methods. Our hypothesis was that the casts prepared by air pressure method have less volume and are more comfortable than those prepared by weight bearing method. Methods: Fifteen transtibial unilateral amputees participated in the study. Two weight bearing and air pressure casting methods were utilized for their residual limbs. The diameters and circumferences of various areas of the residual limbs and positive casts were compared. The volumes of two types of casts were measured by a volumeter and compared. Visual Analogue Scale (VAS) was used to measure the sockets fit comfort. Results: Circumferences at 10 and 15 cm below the patella on the casts were significantly smaller in air pressure casting method compared to the weight bearing method (p=0.00 and 0.01 respectively). The volume of the cast in air pressure method was lower than that of the weight bearing method (p=0.006). The amputees found the fit of the sockets prepared by air pressure method more comfortable than the weight bearing sockets (p=0.015). Conclusion: The air pressure casting reduced the circumferences of the distal portion of residual limbs which has more soft tissue and because of its snug fit it provided more comfort for amputees, according to the VAS measurements.
کلیدواژههای انگلیسی مقاله
Transtibial prosthesis, Weight bearing, Cast, Air pressure.
نویسندگان مقاله
بهنام حاجی آقایی | behnam hajiaghaei
department of orthotics and prosthetics, faculty of rehabilitation sciences, iran university of medical sciences, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
اسماعیل ابراهیمی | ismail ebrahimi
department of physiotherapy, iran university of medical sciences, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
مجتبی کامیاب | mojtaba kamyab
department of orthotics and prosthetics, faculty of rehabilitation sciences, iran university of medical sciences, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
حسن سعیدی | hassan saeedi
department of orthotics and prosthetics, faculty of rehabilitation sciences, iran university of medical sciences, tehran, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
مریم جلالی | maryam jalali
نشانی اینترنتی
http://mjiri.iums.ac.ir/browse.php?a_code=A-10-1-973&slc_lang=en&sid=en
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/18/article-18-568039.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Prosthetics and Orthotics
نوع مقاله منتشر شده
Original Research
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات