این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 27 بهمن 1404
Iranian Journal of Nuclear Medicine
، جلد ۲۶، شماره ۲، صفحات ۶۸-۷۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparing diagnostic performance of 131I-metaiodobenzylguanidine (131I-MIBG) and 99mTc-hydrazinonicotinyl-Tyr3-Octreotide (99mTc-HYNIC-TOC) in diagnosis and localization of pheochromocytoma and neuroblastoma
چکیده انگلیسی مقاله
Introduction: The present study was aimed to assess the diagnostic performance of the two imaging methods of 131I-metaiodobenzylguanidine (131I-MIBG) and 99mTc-hydrazinonicotinyl-Tyr3-Octreotide (99mTc-HYNIC-TOC) in diagnosis and localization of pheochromocytoma and neuroblastoma. Methods: This study was conducted on 40 consecutive patients with positive pathological results for pheochromocytoma or neuroblastoma. The patients underwent both I-131 131I-MIBG and octreotide scintigraphies. By using the findings of cytopathology, biomarkers, imaging studies, as well as the results of a six-month follow-up, a composite reference standard (CRS) was defined as the diagnostic gold standard. Results:Overall comparison of these two agents revealed higher sensitivity for 131I-MIBG than octreotide study both in patient-based analysis (100% vs. 80.9%, respectively), and lesion-based analysis (94.4% vs. 80.56%, respectively). In pheochromocytoma 131I-MIBG and octreotide are both highly sensitive (100%), while 131I-MIBG is more specific (100% vs. 87.5%). In neuroblastoma, 131I-MIBG is more sensitive than octreotide (100% vs. 81.25%). Conclusion: Our study shows superiority of 131I-MIBG over octreotide scanning in detection of both neuroblastoma and pheochromocytoma lesions. However, a combination of these two diagnostic tools provides more complete information on the nature and the site of lesions. The first suggested study is 131I-MIBG scanning, and if it is not available, or detecting precise location of all lesions is of concern, octreotide scanning can be helpful as a complementary study. Furthermore, in case of octreotide positive lesions, follow-up can be performed with octreotide scan with less radiation burden.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
Alireza Emami-Ardekani |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Arefe Mirzabeigi |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Armaghan Fard-Esfahani |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Babak Fallahi |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Davood Beiki |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Arman Hassanzadeh-Rad |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Parham Geramifar |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
Mohammad Eftekhari |
Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
نشانی اینترنتی
http://irjnm.tums.ac.ir/article_31620_2587e1bb6e260efba9a7ff280c4e9137.pdf
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/57/article-57-679518.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات