این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 23 بهمن 1404
Medical Journal of Islamic Republic of Iran
، جلد ۲۰، شماره ۴، صفحات ۱۹۲-۱۹۷
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A new method for ideal dose distribution of two adjacent fields for external beam radiation therapy
چکیده انگلیسی مقاله
Abstract Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a possibility of introducing very large dosage errors across the junction. Consequently, this region is at risk for severe complications if it is overdosed, or tumor recurrence if it is underdosed. Methods: For prevention of adjacent field overlapping a new method is introduced. In this method the patient’s couch of the treatment machine is rotated for 90º clockwise and counterclockwise. Then the gantry is rotated for α and β that are measured by geometrical methods in opposite direction for each field. The adjacent fields have a common edge and then the overlap region in treatment volume is eliminated. Results: By phantom dosimetry, the maximum dose in the junctional volume of the two adjacent treatment fields is measured to be 102%. This technique provides an inhomogeneity of about 2%. Conclusion: In some cases, the measurements have shown that the dose inhomogeneity is as large as 45%. Compared with the dynamic intensity-modulated radiotherapy (IMRT), this technique also provides a superior dose homogeneity such that inhomogeneity becomes about 2%.
کلیدواژههای انگلیسی مقاله
Adjacent fields, External radiation therapy, Dosimetry
نویسندگان مقاله
محمدجواد طهماسبی بیرگانی | m j tahmasebi birgani
medical physics and radiation therapy departments, jundishapur university of medicalsciences, ahwaz, iran
m انصاری | m. ansari
radiation therapy department, jundishapur university of medical sciences, ahwaz, iran
محمدعلی بهروز | m a behrooz
medical physics department, jundishapur university of medical sciences, ahwaz, iran
نشانی اینترنتی
http://mjiri.iums.ac.ir/browse.php?a_code=A-10-1-235&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات