In vivo biocompatibility of Resilon compared with gutta-percha in a pre-clinical model
چکیده انگلیسی مقاله
Background: The aim of this study was to investigate in vivo biocompatibility of Resilon, compared with gutta-percha, at short and long-term following implantation in a rat subcutaneous implantation model. Materials and Methods: Male Wistar rats were implanted subcutaneously with either Resilon or gutta-percha or were sham controls. Tissues were harvested at 8 days or 60 days after implantation and were evaluated histologically for inflammation and fibrous encapsulation. The severity of histologic injury, scored on a scale of 0-4 and quantitative analysis of the capsule wall thickness were determined for statistical analysis. Data were analyzed by Student t -test, one-way analysis of variance, Kruskal-Wallis or Mann-Whitney’s tests as appropriate. A value of P ≤ 0.05 was considered statistically significant. Results: No behavioral changes or visible signs of physical impairment were observed at 8 days or 60 days post-implantation. Histopathologic observation of the implanted sites at each timepoint showed that both Resilon and gutta-percha implants induced foreign body reaction, showing minimal to mild inflammatory reactions in most cases, which diminished significantly with time. Compared with gutta-percha, the capsule wall was thinner ( P > 0.05) after Resilon implantation at day 8 and significantly ( P = 0.01) thicker at day 60. In addition, capsule wall thickness showed a trend to increase with time after implantation in the Resilon groups ( P > 0.05), opposed to the significant decrease ( P = 0.016) observed after implantation in the gutta-percha groups, suggesting lesser long-term biocompatibility of Resilon. Conclusion: Our findings validate Resilon as an in vivo biocompatible material. However, our data suggest that long-term biocompatibility of Resilon, despite validated, is inferior to that of guttapercha control. Key Words: Endodontic materials, gutta-percha, rat, Resilon, subcutaneous implantation
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
میگویل cardoso | miguel cardoso
رودریگو f مارکوس | rodrigo f marques
ماریا francelina lopes | maria francelina lopes
antónio s cabrita | antónio s cabrita
joão میگویل سانتوز | joão miguel santos
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/1504
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات