این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 29 بهمن 1404
Dental Research Journal
، جلد ۹، شماره ۱، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Retentiveness of implant-supported metal copings using different luting agents
چکیده انگلیسی مقاله
Background: With regard to potential retrievability of cement-retained implant restorations, the retentive strength of the luting agents is critical. The aim of this study was to evaluate the retention values of implant-supported metal copings using different luting agents. Materials and Methods: Twenty ITI implant analogs and solid abutments of 5.5-mm height were embedded vertically in autopolymerizing acrylic resin blocks. Metal copings with a loop on the occlusal surface were fabricated using base metal alloy (Rexillium III). The copings were luted using eight cements with different retention mechanisms (Panavia F2.0, Fuji Plus, Fleck’s, Poly F, Fuji I, Temp Bond, GC-free eugenol, and TempSpan) under static load of 5 kg (n=10). All specimens were incubated at 37°C for 24 hours, conditioned in artificial saliva for 7 days and thermocycled for 5000 cycles (5-55°C). The dislodging force was measured using a universal testing machine at a crosshead speed of 5 mm/min. Statistical analyses were performed using Kruskal-Wallis (α=0.05) and Mann-Whitney tests with Bonferroni correction (α=0.001). Results: Fuji Plus and TempSpan had the highest and the least mean retentive strength, respectively (320.97±161.47, 3.39±2.33). There was no significant difference between Fuji Plus, Fleck’s, Ploy F, and Panavia F2.0. These cements were superior to provisional cements and Fuji I (P< 0.001) which showed statistically same retentive strength. Conclusion: Within the conditions of this study, the resin modified glass ionomer, zinc phosphate, zinc polycarboxylate, and Panavia F2.0 had statistically the same retentive quality and are recommended for definitive cementation of single implant-supported restorations. The provisional cements and glass ionomer may allow retrievability of these restorations. Key Words: Cementation methods, dental cement, dental prosthesis/retention, dental prosthesis, implant-supported
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
فرحناز نجاتی دانش | farahnaz nejatidanesh
امید صوابی | omid savabi
مازیار ابراهیمی | maziar ebrahimi
غزال صوابی | ghazal savabi
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/889
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات